10 year heat exchanger warranty on logic - ideal …

10 Year Heat Exchanger Warranty on Logic - Ideal …

Ideal Boilers is today (Oct 2) introducing a free 10-year warranty on the heat exchangers in all Logic and Logic+ boiler ranges, when installed with an Ideal System Filter.. Installers are familiar with the peace of mind which comes when commissioning a boiler from the Ideal Logic+ boiler range, thanks to the 7-year warranty on parts and labour.

Get a Quote
logic+ combi boiler | ideal boilers

Logic+ Combi Boiler | Ideal Boilers

Our Logic+ Combi range comes complete with a 7 year parts and labour warranty* and a 10 year warranty on the heat exchanger**. It is one of the only boilers in the UK to receive Quiet Mark accreditation for its quiet operation.

Get a Quote
genuine ideal boiler heat exchangers, ideal heat …

Genuine Ideal Boiler Heat Exchangers, Ideal Heat …

Visit Keeptheheaton for GENUINE Ideal Boiler Heat Exchangers. Every Part You See is in Stock. Order before 4.00pm Mon-Fri for Next Day Delivery

Get a Quote
ideal boilers | central heating | screwfix

Ideal Boilers | Central Heating | Screwfix

Buy Ideal Boilers at Screwfix. High efficiency boilers, for both new and replacement installations. Click & collect next day or Free delivery available.

Get a Quote
heating leak but from ideal logic boiler or pipework

Heating leak but from Ideal Logic boiler or pipework

2019-12-3 · No you cant use the HW with the boiler isolated unless of course you have an immersion heater in which case you can, you may have a pinholed heat exchanger that is passing into the Condensate pipe so you dont notice it, only way to test is switch the boiler off and see if there is a drip from the condensate with the boiler switched off

Get a Quote
ideal boiler f3 fault code - ephg.limited

Ideal Boiler F3 Fault Code - ephg.limited

2020-1-1 · How can water damage occur on a boiler? Will my boiler engineer test the heat exchanger for leaks? What do I need to do if my heat exchanger is leaking? Are leaking heating pumps easy to spot? What could have caused the pump to leak? Can I release pressure from the boiler? What does the fan speed have to do with the F3 fault code on my Ideal

Get a Quote
why has ideal isar he24 heat exchanger broken

Why has IDEAL ISAR HE24 Heat Exchanger broken

2013-6-4 · Reply to Why has IDEAL ISAR HE24 Heat Exchanger broken? in the Central Heating Forum area at PlumbersForums.net. Plumbing questions, answers, tips …

Get a Quote
18 month old ideal logic+ boiler (split heat exchanger

18 month old Ideal Logic+ boiler (Split heat exchanger

I have a Ideal Independent C35 combi boiler that was installed when renevating my house. The property was empy for the first winter then we moved in for the next. The boiler started losing pressure and water escaped through the condensator pipe. It was found the heat exchanger was …

Get a Quote
combi boiler plate heat exchanger faults and …

Combi Boiler Plate Heat Exchanger Faults and …

Please read our Legal Disclaimer. Plate heat exchangers in combi boilers are secondary heat exchangers. There are other types of secondary heat exchanger and there are some combination boilers like the Potterton Puma and Lynx or the Ferroli F24, F30, Modena and Domina ranges, or Worcester 24i Junior and 28i Junior that don’t use secondary heat exchangers at all but the majority of combi

Get a Quote
ideal boiler fd fault code - ephg.limited

Ideal Boiler FD Fault Code - ephg.limited

2020-1-1 · As you open the boiler’s external filling loop valve, you’ll see pressure start to climb. Stop when you get to 1.3 bar. If lack of water is causing the FD fault code to be displayed on your Ideal boiler, this will fix the problem. I topped up my boiler, it started losing pressure and now the FD fault code is …